,Cathode Ray Tubes,Ceramic Tubes,CFA,chemical synthesis,chromenes,CO2 sensors,Communication,composite membranes,condensed heterocycles,Control Tubes,CWT,database,Devices,Diodes,Discharger,Display Tubes,Electron Tubes,Electron,antitumor,artificial organs,artificial skin,Attenuators,Audio tubes,Backward Wave Oscillator,Band filtering,Beam tubes,biocompatibility,biomaterials,biosensors,Broadcast,Broadcasting Tubes,Broadcasting,carbon dioxide isolation3CX300A1,4CX400A,4CX800A,4X150A,6360,6BK4,6BQ7.6C19,6C33C,6D22S,6N1P,6S19P,7034,813,829A,832A,833A,absorbent,Acquisition,Aircraft,Amateur Radio,Amateur,Amplifiers,Antenna amplifiers,anticancer compounds,antitumor agent,Broadcast Tubes,Transmitting Tubes,Transmitting,Broadcast,Russia,component,Navigator,product,characteristics,tube,technical,information,diagram">
GU-100B
TRIODE
The GU-100B triode is used as an oscillator in stationary industrial RF heating generators and as a power
amplifier in stationary industrial transmitters.
GENERAL
Cathode: directly heated.
Envelope: metal-ceramic.
Cooling: forced air.
Working position: upright with anode down.
Height: at most 265 mm.
Diameter: at most 150 mm.
Mass: at most 7 kg.
00061.jpg)
A - anode; C - grid; K1, K2 - cathode
| OPERATING ENVIRONMENTAL CONDITIONS | |
| Vibration loads: | |
| frequencies, Hz | 1-35 |
| acceleration, m/s² | 5 |
| Multiple impacts with a peak acceleration of m/s² | 150 |
| Ambient temperature, °C | -10 to +55 |
| Relative humidity at up to ±25 °C without moisture condensation, % | 98 |
|
BASIC DATA Electrical Parameters |
|
| Filament voltage, V | 5 |
| Filament current, A | 62-82 |
| Peak anode current (at filament voltage 5 V, anode voltage 0.5 kV, grid voltage 500 V, bias voltage -400 V), A, at least | 6 |
|
Negative cutoff voltage, absolute (at filament voltage 5 V, anode voltage 6 kV, anode current 0.1 A), V, at most |
350 |
| Gain coefficient (at filament voltage 5 V, anode voltages 0.5 kV and 2 kV, anode current 3A) | 15-28 |
| Output power in self-excitation mode, kW: | |
| at up to 10 MHz (at filament voltage 5 V, anode voltage 8 kV, grid bias voltage -350 V, anode current 1.6 A, grid current 0.4 A) | 10 |
| at 10-150 MHz (at filament voltage 5 V, anode voltage 6 kV, grid bias voltage -350 V, anode current 1.35 A, grid current 0.32 A) | 6.3 |
| Interelectrode capacitance in a grounded-cathode circuit, pF: | |
| input, at most | 50 |
| output, at most | 1.2 |
| transfer,at most | 30 |
| Limit Operating Values | |
| Filament voltage, V | 5.3 |
| Anode voltage (DC), kV: | |
| at frequencies up to 10 MHz | 8 |
| at frequencies 10-150 MHz | 6 |
| Negative bias voltage, absolute value, V | 550 |
| Filament current (peak value), A | 160 |
| Grid current (DC component), A: | |
| at frequencies up to 10 MHz | 0.5 |
| at frequencies up to 10-150 MHz | 0.45 |
| Dissipation, W: | |
| anode | 6x10³ |
| grid | 400 |
| Operating frequency, MHz | 150 |
| Envelope temperature (except for anode) at the hottest point, °C | 175 |
| Anode temperature, °C | 200 |
00081.jpg)
Averaged Anode-Grid Characteristic Curves:
Uf = 50V;
_____ anode-grid;
- - - grid