,Cathode Ray Tubes,Ceramic Tubes,CFA,chemical synthesis,chromenes,CO2 sensors,Communication,composite membranes,condensed heterocycles,Control Tubes,CWT,database,Devices,Diodes,Discharger,Display Tubes,Electron Tubes,Electron,antitumor,artificial organs,artificial skin,Attenuators,Audio tubes,Backward Wave Oscillator,Band filtering,Beam tubes,biocompatibility,biomaterials,biosensors,Broadcast,Broadcasting Tubes,Broadcasting,carbon dioxide isolation3CX300A1,4CX400A,4CX800A,4X150A,6360,6BK4,6BQ7.6C19,6C33C,6D22S,6N1P,6S19P,7034,813,829A,832A,833A,absorbent,Acquisition,Aircraft,Amateur Radio,Amateur,Amplifiers,Antenna amplifiers,anticancer compounds,antitumor agent,Transmitting Pulse Tubes,Transmitting,Pulse,Russia,component,Navigator,product,characteristics,tube,technical,information,diagram">
GI-13BM
(GI-130M)
TRIODE
The GI-13BM (GI-130M) triode is used in selfexcited oscillator circuits with no external feedback, operating in continuous-wave or pulsed mode with anode modulation in the decimetric wavelength range.
The triode is available in two variants differing in the type of cooling: the GI-13BM with a heat sink for forced air cooling and the GI-130M with no heat sink for other systems of cooling.
GENERAL
Cathode: indirectly heated, oxide-coated.
Envelope: metal-ceramic.
Cooling: forced air.
Height: 88.5 mm with heat sink, 63.7 mm with no heat sink.
Diameter: 46 mm with heat sink, 26.3 mm with no heat sink.
Mass: 120 g with heat sink, 60 g with no heat sink.
(2)00081.jpg)
(2)00082.jpg)
KP - cathode and heater; P - heater; C - grid; A - anode
| OPERATING ENVIRONMENTAL CONDITIONS | |
| Vibration loads: | |
| frequencies, Hz | 5-2,000 |
| acceleration, m/s² | 98 |
| Multiple impacts with acceleration, m/s² | 735 |
| Ambient temperature, °C | -60 to +100 |
| Relative humidity at up to +40 °C, % | 98 |
|
BASIC DATA Electrical Parameters |
|
| Heater voltage, V | 12.6 |
| Heater current, A | 0.6-0.7 |
| Mutual conductance (at anode voltage 400 V, grid voltage change 0.5 V, anode current 15mA), mA/V | 8-12 |
| Penetration factor (at anode voltage change from 400-800 V, anode current 15 mA), % | 0.7-1.5 |
| Anode current (at anode voltage 400 V), mA | 35-65 |
| Interelectrode capacitance, pF: | |
| input | 9.5-12 |
| output | 0.16-0.25 |
| transfer | 2.45-2.95 |
| Warm up time, s, at most | 60 |
| Output power in pulsed operation (at peak anode voltage 1.5 kV, wavelength 12.4 cm, pulse duration 3-7µs, 1 /duty factor 150-200), W, at least | 110 |
| Limit Operating Values | |
| Heater voltage, V: | |
| over 500 h in CW operation | 10.5-11.5 |
| over 200 h of CW operation | 12-13.2 |
| over 500 h of pulsed operation | 12-13.2 |
| Anode voltage: | |
| DC, V | 900 |
| DC with cold cathode, kV | 1 |
| peak value (with pulse duration at most 5 µs), kV | 4 |
| Grid voltage, instantaneous value (with pulse duration at most 5 µs), V | -150 to +80 |
| Cathode current: | |
| r.m.s. value, mA | 150 |
| peak value (with pulse duration at most 5 µs), A | 3.5 |
| Dissipation, W: | |
| anode: | |
| with forced cooling | 80 |
| with no forced cooling | 20 |
| grid | 2 |
| Cathode heating time, s, at least | 45 |
| Wavelength, cm, at least | 9 |
(3)00091.jpg)
Anode Characteristic Curves