,Cathode Ray Tubes,Ceramic Tubes,CFA,chemical synthesis,chromenes,CO2 sensors,Communication,composite membranes,condensed heterocycles,Control Tubes,CWT,database,Devices,Diodes,Discharger,Display Tubes,Electron Tubes,Electron,antitumor,artificial organs,artificial skin,Attenuators,Audio tubes,Backward Wave Oscillator,Band filtering,Beam tubes,biocompatibility,biomaterials,biosensors,Broadcast,Broadcasting Tubes,Broadcasting,carbon dioxide isolation3CX300A1,4CX400A,4CX800A,4X150A,6360,6BK4,6BQ7.6C19,6C33C,6D22S,6N1P,6S19P,7034,813,829A,832A,833A,absorbent,Acquisition,Aircraft,Amateur Radio,Amateur,Amplifiers,Antenna amplifiers,anticancer compounds,antitumor agent,Transmitting Pulse Tubes,Transmitting,Pulse,Russia,component,Navigator,product,characteristics,tube,technical,information,diagram">
GU-30
DOUBLE BEAM-POWER TETRODE
The GI-30 double beam-power tetrode is used in pulse-operation circuits of RF equipment.
GENERAL
Cathode: indirectly heated, oxide-coated.
Envelope: glass, no-base.
Height: at most 110 mm.
Diameter: at most 61 mm.
Mass: almost 125g.
00021.jpg)
1 - heater; 2 - grid 2; 3 - common grid 2; 4 - cathode and beam-forming plates; 5,7- heater; 6 - grid 1 of first tetrode; A1 - anode of first tetrode; A2 - anode of second tetrode
| OPERATING ENVIRONMENTAL CONDITIONS | |
| Vibration loads: | |
| frequencies, Hz | 20-200 |
| acceleration, m/s² | 59 |
| Multiple impacts with acceleration, m/s² | 343 |
| Single impacts with acceleration, m/s² | 1,470 |
| Linear loads with acceleration, m/s² | 240 |
| Ambient temperature, °C | -60 to+135 |
| Relative humidity at up to +40 °C, % | 98 |
|
BASIC DATA Electrical Parameters |
|
| Heater voltage, V | 12.6 |
| Heater current, A | 1-1.25 |
| Anode current (at anode voltage 250 V, grid 1 voltage -11 V of first tetrode, grid 1 voltage -100 V of second tetrode, grid 2 voltage 175 V), mA | 35-82 |
| Grid 2 current (at anode voltage 250 V, grid 1 voltage -11 V of first tetrode, grid 1 voltage -100 V of second tetrode, grid 2 voltage 175 V), mA, at most | 10 |
| Interelectrode capacitance, pF: | |
| input | 13-17 |
| output | 5-9 |
| transfer, at most | 0.1 |
| Warm up time, s, at most | 50 |
| Peak anode current over 1,000 h of service, A, at least | 7.5 |
| Limit Operating Values | |
| Heater voltage, V | 11.3-13.9 |
| Anode voltage, kV | 5 |
| Grid voltage, V | 850 |
| Peak anode current, A | 9 |
| Dissipation, W: | |
| anode | 15 |
| grid 2 | 3 |
| Warm up time, s, at last | 60 |
| Envelope temperature, °C | 200 |
00031.jpg)
Characteristic Curves Showing Anode Dissipation Pa max versus Ambient Temperature (at bulb temperature Tb 200 °C)