,Cathode Ray Tubes,Ceramic Tubes,CFA,chemical synthesis,chromenes,CO2 sensors,Communication,composite membranes,condensed heterocycles,Control Tubes,CWT,database,Devices,Diodes,Discharger,Display Tubes,Electron Tubes,Electron,antitumor,artificial organs,artificial skin,Attenuators,Audio tubes,Backward Wave Oscillator,Band filtering,Beam tubes,biocompatibility,biomaterials,biosensors,Broadcast,Broadcasting Tubes,Broadcasting,carbon dioxide isolation3CX300A1,4CX400A,4CX800A,4X150A,6360,6BK4,6BQ7.6C19,6C33C,6D22S,6N1P,6S19P,7034,813,829A,832A,833A,absorbent,Acquisition,Aircraft,Amateur Radio,Amateur,Amplifiers,Antenna amplifiers,anticancer compounds,antitumor agent,Transmitting Pulse Tubes,Transmitting,Pulse,Russia,component,Navigator,product,characteristics,tube,technical,information,diagram">
GI-31
TRIODE
The GI-31 triode is used as a RF oscillator for pulsed operation with anode keying in the decimetric wavelength range.
GENERAL
Cathode: indirectly heated, oxide-coated.
Envelope: metal-ceramic.
Height: at most 35 mm.
Diameter: at most 25.8 mm.
Mass: almost 18g.
00041.jpg)
A - anode; C - grid; KP - cathode and heater; P - heater
| OPERATING ENVIRONMENTAL CONDITIONS | |
| Vibration loads: | |
| frequencies, Hz | 1-600 |
| acceleration, m/s² | 98 |
| Multiple impacts with acceleration, m/s² | 392 |
| Single impacts with acceleration, m/s² | 4,900 |
| Linear loads with acceleration, m/s² | 980 |
| Ambient temperature, °C | -60 to +100 |
| Relative humidity at up to +35 °C, % | 98 |
|
BASIC DATA Electrical Parameters |
|
| Heater voltage (AC or DC), V | 6.3 |
| Heater current, A | 0.9-1 |
| Inverse grid current, µA, at most | 2 |
| Mutual conductance (at anode voltage 350 V, anode current 35 mA), mA/V, at least | 15 |
| Peak cathode emission current (at peak anode and grid voltages 200 V, pulse duration 4-6 µs), A, at least | 15 |
| Peak power output (at peak anode voltages 2.5 kV, peak anode current 2.1 A, pulse duration 3 µs), 1/duty factor 500, wavelength 14-14.5 cm) kW at least | 1.5 |
| Interelectrode capacitance, pF: | |
| input | 3.5 |
| outut,at most | 0.04 |
| transfer | 2-2.7 |
| Limit Operating Values | |
| Heater voltage, V | 6-6.6 |
| Peak anode voltage, kV | 2.8 |
| Dissipation, W: | |
| anode | 12 |
| grid | 0.5 |
| Peak anode current, A | 2.5 |
| Peak grid current, A | 1.3 |
| Envelope temperature, °C | 200 |
| Warm up time, s | 15 |
| Operating frequency, MHz | 2,100 |
| Maximum pulse duration, µs, at most | 3 |
| Minimum 1/duty factor, at least | 400 |
|
Standard Operating Conditions (Anode Keying) |
|
| Heater voltage, V | 6.3 |
| Peak anode voltage, kV | 2.5 |
| Peak anode current, A | 2.1 |
| Pulse duration, µs | 0.6-3 |
| 1/duty factor | 500 |
| Wavelength, cm, at least | 14 |
| Peak power output, W | 1,500 |
00051.jpg)
Averaged Characteristic Curves in Pulsed Operation:
Uf = 6.3V; t = 1µs; frequency 2,000 imp/s
00052.jpg)
Averaged Anode-Grid Characteristic Curves in Pulsed Operation:
Uf = 6.3V; t = 1µs; frequency 2,000 imp/s
00061.jpg)
Averaged Characteristic Curves Showing Peak Oscillator Output Power versus Anode Voltage:
Uf = 6.3V
00062.jpg)
Averaged Characteristic Curves of Efficiency versus Anode Voltage:
Uf = 6.3V