,Cathode Ray Tubes,Ceramic Tubes,CFA,chemical synthesis,chromenes,CO2 sensors,Communication,composite membranes,condensed heterocycles,Control Tubes,CWT,database,Devices,Diodes,Discharger,Display Tubes,Electron Tubes,Electron,antitumor,artificial organs,artificial skin,Attenuators,Audio tubes,Backward Wave Oscillator,Band filtering,Beam tubes,biocompatibility,biomaterials,biosensors,Broadcast,Broadcasting Tubes,Broadcasting,carbon dioxide isolation3CX300A1,4CX400A,4CX800A,4X150A,6360,6BK4,6BQ7.6C19,6C33C,6D22S,6N1P,6S19P,7034,813,829A,832A,833A,absorbent,Acquisition,Aircraft,Amateur Radio,Amateur,Amplifiers,Antenna amplifiers,anticancer compounds,antitumor agent,Transmitting Pulse Tubes,Transmitting,Pulse,Russia,component,Navigator,product,characteristics,tube,technical,information,diagram">
GI-7B
(GI-70B)
MICROWAVE TRIODE
The GI-7BT (GI-70BT) triode is used for continuouswave or pulsed operation with anode modulation, as an oscillator and an amplifier.
The triode is available in two variants differing in the type of cooling: the GI-7BT with a heat sink for forced air cooling and the GI-70BT with no heat sink for other systems of cooling.
GENERAL
Cathode: indirectly heated, oxide-coated.
Envelope: metal-ceramic with ring leads of cathode, heater and grid.
Cooling: forced air.
Height: at most 110.5 mm with heat sink, 97 mm with no heat sink.
Diameter: at most 65 mm with heat sink, 47 mm with no heat sink.
Mass: at most 330 g with heat sink, 170 g with no heat sink.
(3)00091.jpg)
(3)00092.jpg)
KP - cathode and heater; P - heater; C - grid; A - anode
| OPERATING ENVIRONMENTAL CONDITIONS | |
| Vibration loads: | |
| frequencies, Hz | 5-1,000 |
| acceleration, m/s² | 98 |
| Multiple impacts with acceleration, m/s² | 735 |
| Ambient temperature, °C | -60 to +100 |
| Relative humidity at up to +40 °C, % | 98 |
|
BASIC DATA Electrical Parameters |
|
| Heater voltage, V | 12.6 |
| Heater current, A | 1.8-2.05 |
| Mutual conductance (at anode voltage 1.3 kV, grid voltage change 1 V, anode current 150 mA), mA/V | 20-26 |
| Penetration factor (at anode voltage 1.3 kV, anode voltage change 200 V, anode current 150mA), % | 1.2-1.8 |
| Operating point (negative grid voltage at anode voltage 1.3 kV, anode current 150 mA), V | 12.5-7.5 |
| Interelectrode capacitance, pF: | |
| input | 10-12.5 |
| output | 4.2-5 |
| transfer | 0.055-0.95 |
| Warm up time, s, at most | 90 |
| Output power: | |
| in CW operation (at heater voltage 11.6V, anode voltage 1.05 kV, anode current 300 mA, wavelength 18.5 cm), W, at least | 40 |
| in pulsed operation (at heater voltage 12.6 V, peak anode voltage 9 kV, peak anode current 7.5 A, wavelength 10 cm), kW, at least | 12 |
| Output power over 650 h of service (at heater voltage 11.6V, anode voltage 1.05 kV, anode current 300 mA, wavelength 18.5 cm), W, at least | 32 |
| Limit Operating Values | |
| Heater voltage, V | 12-13.2 |
| Anode voltage, kV: | |
| pulsed operation | 9 |
| instantaneous value in CW operation | 5 |
| DC voltage in continuous operation | 2.5 |
| DC voltage with cold cathode | 3 |
| Grid voltage, V: | |
| pulsed operation | -900 to +600 |
| CW operation, instantaneous value | -400 to +80 |
| Cathode current, A: | |
| r.m.s. value | 0.6 |
| DC component under conditions of class  | |
| without modulation | 0.4 |
| instantaneous value under conditions of class  without modulation | 1.25 |
|
Anode current (DC component in pulsed operation), A |
7.5 |
| Dissipation, W: | |
| anode | 350 |
| grid | 7 |
| Wavelength,cm | 9 |
| Cathode heating time, min. | 1.5 |
| Pulse duration, µs | 10 |
| Temperature, °C: | |
| anode end face | 200 |
| anode heat sink | 160 |
| cathode lead | 100 |
| grid lead | 200 |
| outer ceramic parts | 250 |
| Resistance in grid circuit, kOm | 10 |
(4)00021.jpg)
Averaged Anode-Grid Characteristic Curves in Pulsed
Operation:
Uf= 12.6V
(4)00022.jpg)
Averaged Characteristic Curves Showing Oscillator
Output Power versus Anode Voltage in ContinuousWave Generation:
Uf=12.6V;A= 18.5cm