,Cathode Ray Tubes,Ceramic Tubes,CFA,chemical synthesis,chromenes,CO2 sensors,Communication,composite membranes,condensed heterocycles,Control Tubes,CWT,database,Devices,Diodes,Discharger,Display Tubes,Electron Tubes,Electron,antitumor,artificial organs,artificial skin,Attenuators,Audio tubes,Backward Wave Oscillator,Band filtering,Beam tubes,biocompatibility,biomaterials,biosensors,Broadcast,Broadcasting Tubes,Broadcasting,carbon dioxide isolation3CX300A1,4CX400A,4CX800A,4X150A,6360,6BK4,6BQ7.6C19,6C33C,6D22S,6N1P,6S19P,7034,813,829A,832A,833A,absorbent,Acquisition,Aircraft,Amateur Radio,Amateur,Amplifiers,Antenna amplifiers,anticancer compounds,antitumor agent,Broadcast Tubes,Transmitting Tubes,Transmitting,Broadcast,Russia,component,Navigator,product,characteristics,tube,technical,information,diagram">
GU-10B
TRIODE
GENERAL
Cathode: directly heated, carbonized thoriated tungsten.
Envelope: glass-to-metal.
Cooling: forced air.
Height: at most 330 mm.
Diameter: at most 128 mm.
Mass: at most 6 kg.
| OPERATING ENVIRONMENTAL CONDITIONS | |
| Ambient temperature, °C | -10 to +55 |
| Relative humidity at up to +25°C, % | 98 |
|
BASIC DATA Electrical Parameters |
|
| Filament voltage, V | 7 |
| Filament current, A | 70-80 |
| Mutual conductance (at anode voltage 2 kV, anode currents 2.5 and 3.5 A), mA/V | 15-25 |
| Gain coefficient (at anode voltages 2 and 3 kV and anode current 2.5 A) | 45-55 |
| Anode current at zero grid voltage (at anode voltage 5 kV), A | 0.6-1.2 |
| Interelectrode capacitance, pF: | |
| input, at most | 40 |
| output, at most | 1.6 |
| transfer, at most | 34 |
| Limit Operating Conditions | |
| Filament voltage, V | 7-7.3 |
| Anode voltage (DC), kV | 8 |
| Filament starting current, A | 115 |
| Anode modulation factor | 1 |
| Dissipation, W: | |
| anode | 1.0x104 |
| grid | 300 |
| Operating frequency, MHz | 26 |
| Temperature at envelope, and seals, °C | 150 |